Normally, ipmi_ui starts up in a full-screen format. Users may wish to use the --output-event-state option to output the analyzed state. For the latest NCC release, see the Downloads … You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. It's rather crude, and primarily for testing OpenIPMI, but it has some use beyond that so it is provided. Monitoring of IPMI SEL events can be achieved using ipmievd tool . Ipmi-sel does not inform the user if an event is particularly good or bad, just that the event occurred. It can take a wee while for the BMC to boot and configure itself etc before it's ready to work though, it's not instant. It is a part of ipmitool package. The need to configure Nutanix Time Server will also make sure that the interaction between components which requires synchronization with other hosts is working as expected. Listed below are general IPMI options, tool specific options, trouble shooting information, workaround information, examples, and known issues. The left window shows the output of commands, the right window shows the logs from OpenIPMI. The Nutanix cluster from this perspective is no exception. ipmitool event 2 Nutanix Engineering is aware of the issue and is working on a fix in a future release. You agree to grant Intel a non- exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. In this article we’ll explore the steps on how to configure Nutanix Time Server client using the command line. After upgrading to FreeNAS 11.3 BETA, I have received the following alert on my HPE Microserver Gen8: Warning: IPMI SEL low space left: 0 bytes (100% used). Presently 'sel time set' doesn't account 'minute' difference between timezone. There is no way to clear the IPMI System Event Log from the web UI, therefore you have to type as root in the shell: ipmitool sel clear ipmievd sel daemon Now , to simulate generation of SEL events , we will execute the following command. The ipmi_ui program connects to an IPMI system, and allows access to IPMI entities and sensors and OpenIPMI controls. Dependencies: After upgrading BIOS and BMC, also upgrade NCC to version 3.8.0.1 or higher to support the new SEL log messages. This patch adds minute difference to delta_hour caluclation so that it sets time properly. Try simply providing power, don't switch the server on, just leave it for alone for 5 mins, then try IPMI … IPMI should be responsive no matter what OS you plan on using. So depending on host timezone it may set time to +/-30 mins. # rpm -qf /usr/sbin/ipmievd ipmitool-1.8.11-12.el6.x86_64 To send SEL events to syslog, execute the following command.